PC/104-Plus PC/104 PC test card Doctor display card
| PC test card | Doctor display card | ||
| CV04PC/104(ISA) | (Discontinued) | CV01PC/104(ISA) | (Discontinued) |
| CV04PC/104v1.1(ISA) | CV01PC/104v1.1(ISA) | ||
| CV04PC/104P(PCI) | CV01PC/104P(PCI) | ||
| CV04PC/104Pv1.1(PCI) | CV01PC/104Pv1.1(PCI) | ||
| CV04PC/104P+I(PCI+ISA) | Discontinued | CV01PC/104P+I(PCI+ISA) | (Discontinued) |
| CV04PC/104P+Iv1.1(PCI+ISA) | CV01PC/104P+Iv1.1(PCI+ISA) | ||
| Other PC/104 product | inquiry | ||
* PCI card plugged into connector figure
| CV04PC/104 PC/104(ISA) PC test card | (Discontinued) |
| CV04PC/104v1.1 PC/104(ISA) PC test card | |
1. Suitable for PC/104 ISA bus....compatible system.
2. LED inductor: +12V, - 12V, VCC(+5V), -5V, GND(GraND), RESET, RDY(I/O check ReaDY).
a. RESET LED always light, mother board stand in RESET status; repair it, mother board working.
b. RDY LED always light, I/O Port stand in READY status; repair it, mother board working.
c. +12V, -12V, VCC, - 5V, GND must always light, otherwise input power source
must be "open" happened.
3-1. A0-A9 10bit range Port 80H/300H decoding,
Error code display in Digits (hexadecimal) and LED(D0-D7 binary) display.
3-2 CV04PC/104v1.1 add Port 80H+84H/300H+304H decoding.
4. After mother board power on, run POST(=Power-On-Self-Test) immediately, and use
Test card read BIOS check point value, compare Error code display value with BIOS
Error code message, will know defective position. Also can use Test card Port 80h/300h
for software program check point display.
| CV04PC/104P PC/104-Plus(PCI) PC test card |
| CV04PC/104Pv1.1 PC/104-Plus(PCI) PC test card |
1. Suitable for PC/104-Plus PCI bus....compatible system.
2. LED inductor: +12V, - 12V, VCC(+5V), GND(GraND), RST(ReSet), FRAME,
CBE0, CBE1, CBE2, CBE3.
a. RST LED always light, mother board stand in RESET status; repair it, mother board working.
b. CBE0, CBE1, CBE2, CBE3, FRAME represent bus status, always light or none, must repair it,
mother board working.
c. +12V, -12V, VCC, GND must always light, otherwise input power source must be "open" happened.
3. This test card working power source can choose 3.3V/5V(Select Jumper).
4-1. AD0-AD31 full range 32bit PORT-80H/300H decoding,
Error code display in Digits (hexadecimal) and LED(D0-D7 binary) display.
4-2 CV04PC/104Pv1.1 add Port 80H+84H/300H+304H decoding.
5. After mother board power on, run POST (=Power-On-Self-Test) immediately, and use
Test card read BIOS check point value, compare Error code display value with BIOS
Error code message, will know defective position. Also can use Test card Port 80h/300h
for software program check point display.
| CV04PC/104P+I(PCI+ISA) PC test card | (Discontinued) |
| CV04PC/104P+Iv1.1(PCI+ISA) PC test card | |
* Combination of CV04PC/104Pv1.1(PCI) + CV04PC/104v1.1(ISA).
| CV01PC/104 PC/104(ISA) Doctor display card | (Discontinued) |
| CV01PC/104v1.1 PC/104(ISA) Doctor display card | |
1. All functions same as CV04PC/104v1.1
2. Difference: Move Digits displayed to one display box, more easier to view error code.
| CV01PC/104P PC/104-Plus(PCI) Doctor display card | (Discontinued) |
| CV01PC/104Pv1.1 PC/104-Plus(PCI) Doctor display card | |
1. All functions same as CV04PC/104P.
2. Difference: Move Digits displayed to one display box, more easier to view error code.
| CV01PC/104P+I(PCI+ISA) Doctor display card | (Discontinued) |
| CV01PC/104P+Iv1.1(PCI+ISA) Doctor display card | |
* Combination of CV01PC/104v1.1(ISA) + CV01PC/104Pv1.1(PCI).
| Home | Index |
Start: 13/09/2006 Update: 04.22.2010