DEBUGGER-4
* Could modify BIOS port 80h(POST code decode address) to other port address,
example 80h+84h, each piece plus U$5.-
CV-40 DEBUGGER-4
Function Description:
* CV-40 is the development of DEBUGGER-2 CARD model: CV-25, 26, 27.
* Suitable for PC 286/386/486/586/PII/PIII... compatible system.
* LED inductor: RST(RESET DRV), RDY(I/O CHECK READY), MEMR, MEMW, IOR,
IOW, +5V, -5V, +12V, -12V.
* Chose RUN(RUN POST=Power-On-Self-Test), ERROR CODE DISPLAY:
(1) DIGITs display for hexadecimal.
(2) Offer two I/O PORT 80H and 300H check point.
(3) Setup AEN signal HIGH/LOW or ENABLE/DISABLE.
A.
Hardware Debug:Read BIOS check point value, compare with BIOS ERROR CODE MESSAGE, will
know defective position.
B.
Software Debug:Use CV-40 for CHECK POINT display, can WRITE value to it, no need to interrupt
program execution.
* Chose SL(SeLect step) for Step by step(trace) function:
Use 40pcs LED display A0-A23 ADDRESS BUS and D0-D15 DATA BUS in binary
system.
(1) When ERROR CODE display nonsense code 00 or FF, can use CV-40 to check
ADDRESS BUS and DATA BUS circuit correct or not.
(2) Can trace BIOS operation.
(3) Can check ADDRESS BUS or DATA BUS circuit open/short or not.
(4) Can check ADDRESS BUS or DATA BUS shortage with other signals or not.
(5) Will know real address when system halted.
CV-41 DEBUGGER-4
* All functions, operations, testing same as CV-40.
* Difference: DIGITs display ADDRESS BUS and DATA BUS codes in hexadecimal for
easy view.
CV-42 DEBUGGER-4
* All functions, operations, testing same as CV-40.
* Difference: With LED and DIGITs synchronous display ADDRESS BUS and DATA BUS,
easier to know all the status.
* Could modify BIOS port 80h(POST code decode address) to other port address,
example 80h+84h, each piece plus U$5.-
| Home | Index |
Start: 23/04/1998 Update: 09.29.2009